MRI system is a high-precision imaging diagnostic equipment, which has high requirements for the installation environment. The NMR signal is a very weak signal, which is susceptible to external interference. As a result, MRI systems often need to be equipped with Faraday cages (shielding rooms) to isolate external RF interference from entering the system. However, the Faraday cage has better attenuation for the radio frequency band, and the shielding effect for the low frequency is relatively limited. Especially for the installation of MRI systems near subways, trains, large transformers, elevators, power transmission cables, etc. Not only must the Faraday cage be configured, but also the active shielding system must be configured to make the MRI system meet the diagnostic requirements.
CSJ-ASH is a high-performance low-frequency electromagnetic field active shielding system developed by Ningbo Chuanshan Jia Electromechanical Co., Ltd. It can effectively shield DC electromagnetic fields, 50Hz/60Hz power frequency electromagnetic fields caused by subways, trains, trams, transmission cables, transformer equipment, elevators, etc. CSJ-ASH consists of three major components: fluxgate high-precision probe, host, and shielding coil. The high-precision fluxgate probe can sense the environmental electromagnetic field interference, and generate the corresponding electrical signal to transmit to the host. After processing, the host outputs a reverse current that follows in real time, and the current generates a reverse magnetic field in the shielding coil to cancel the interference magnetic field, thereby realizing active shielding of low-frequency electromagnetic fields.
1、Dynamic compensation range: 200μT
2、Magnetic field resolution: 10 nT
3、Frequency Range: 0-1000 Hz
4、Magnetic field compensation target: <300nT
5、Power requirements:100/240 VAC 50/60 Hz
6、temperature humidity: 10°C ~ 40°C, 10%~ 90%
Product detail pictures:

Related Product Guide:
Adhering into the basic principle of "quality, assistance, effectiveness and growth", we have attained trusts and praises from domestic and worldwide client for Professional China Mri Site Planning - Low-frequency Electromagnetic Field Active Shielding – ChuanShanJia, The product will supply to all over the world, such as: Berlin, Holland, Cologne, We hope we can establish long-term cooperation with all of the customers, and hope we can improve competitiveness and achieve the win-win situation together with the customers. We sincerely welcome the customers from all over the world to contact us for anything you need to have!Welcome all customers both at home and abroad to visit our factory. We hope to have win-win business relationships with you, and create a better tomorrow.

We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.