sub-head-wrapper"">

China wholesale Mri Site Vibration Solution - Low-frequency Electromagnetic Field Active Shielding – ChuanShanJia

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our products are broadly identified and trustworthy by people and may meet continually modifying financial and social requires of Mri Compatible Minimally Invasive Diagnosis And Treatment System, Portable Mri, Rat/Mouse Body Component Analysis System, If you are interested in any products, please feel free to contact us for further information or please send us email directly, we will reply you within 24 hours and the best quotation will be provided.
China wholesale Mri Site Vibration Solution - Low-frequency Electromagnetic Field Active Shielding – ChuanShanJia Detail:

MRI system is a high-precision imaging diagnostic equipment, which has high requirements for the installation environment. The NMR signal is a very weak signal, which is susceptible to external interference. As a result, MRI systems often need to be equipped with Faraday cages (shielding rooms) to isolate external RF interference from entering the system. However, the Faraday cage has better attenuation for the radio frequency band, and the shielding effect for the low frequency is relatively limited. Especially for the installation of MRI systems near subways, trains, large transformers, elevators, power transmission cables, etc. Not only must the Faraday cage be configured, but also the active shielding system must be configured to make the MRI system meet the diagnostic requirements.

CSJ-ASH is a high-performance low-frequency electromagnetic field active shielding system developed by Ningbo Chuanshan Jia Electromechanical Co., Ltd. It can effectively shield DC electromagnetic fields, 50Hz/60Hz power frequency electromagnetic fields caused by subways, trains, trams, transmission cables, transformer equipment, elevators, etc. CSJ-ASH consists of three major components: fluxgate high-precision probe, host, and shielding coil. The high-precision fluxgate probe can sense the environmental electromagnetic field interference, and generate the corresponding electrical signal to transmit to the host. After processing, the host outputs a reverse current that follows in real time, and the current generates a reverse magnetic field in the shielding coil to cancel the interference magnetic field, thereby realizing active shielding of low-frequency electromagnetic fields.

1、Dynamic compensation range: 200μT

2、Magnetic field resolution: 10 nT

3、Frequency Range: 0-1000 Hz

4、Magnetic field compensation target: <300nT

5、Power requirements:100/240 VAC 50/60 Hz

6、temperature humidity: 10°C  ~ 40°C, 10%~ 90%

 


Product detail pictures:

China wholesale Mri Site Vibration Solution - Low-frequency Electromagnetic Field Active Shielding – ChuanShanJia detail pictures


Related Product Guide:

We're proud from the higher client fulfillment and wide acceptance due to our persistent pursuit of high quality both on product and service for China wholesale Mri Site Vibration Solution - Low-frequency Electromagnetic Field Active Shielding – ChuanShanJia, The product will supply to all over the world, such as: Toronto, Bahrain, Florida, Our company will continue to adhere to the " superior quality, reputable, the user first " principle wholeheartedly. We warmly welcome friends from all walks of life to visit and give guidance, work together and create a brilliant future!
  • The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Aurora from Jordan - 2017.12.19 11:10
    This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Deirdre from Milan - 2017.03.28 12:22

    Related Products